Inspecting burners, Operating fireplace – Desa (V)KC36NE Series User Manual

Page 29

Advertising
background image

www.desatech.com

116238-01E

29

Figure 45 - Typical Flame Pattern

OpTIONAL REMOTE

OpERATION

Note:

The WRC receiver and hand-held re-

mote control kit must be purchased separately

(see Accessories, page 35). Follow installation

instructions on page 26.

1. Turn equipment shutoff valve to ON posi-

tion. You can now turn the burner on and off

with the hand-held remote control unit.

IMPORTANT: Be sure to press the ON/OFF

buttons on the hand-held remote control

unit for up to 3 seconds to assure proper

operation.

2. Press the ON/OFF button to turn the

burner on and off.

OpERATING OpTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower

louver panel on the fireplace. Blower controls

are located on the left side of the switch bracket

to the right just inside the louver panel.

The BK manual blower and the BKT thermo-

statically-controlled blower have an ON setting

and an OFF setting. The blower will only run

when the switch is in the ON position. In the

OFF position, the blower will not operate.
Note for BKT Only:

If you are using BKT

blower with optional thermostat (wall mounted

or remote control) for the fireplace, your fire-

place and blower will not turn on and off at the

same time. The fireplace may run for several

minutes before the blower turns on. After the

heater modulates to the pilot position, the blow-

er will continue to run. The blower will shut off

after the firebox temperature decreases.

The blower helps distribute heated air from

the fireplace. Periodically check the louvers of

the firebox and remove any dust, dirt or other

obstructions that will hinder the flow of air.

INSPECTING bURNERS

Check pilot flame pattern and burner flame pat-

terns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper

flame. Alterations may have occurred during ship-

ping and handling. The pilot is located on the left

hand side of the burner.

OPERATING FIREPLACE

Continued

Pilot
Burner

Ignitor/
Sensor

Figure 44 - Correct Pilot Flame Pattern

Sensing
Rod

The flame must envelope 1/4" of top of the ignitor/

sensor and grounding stem.

If your pilot assembly does not meet these re-

quirements:

• Turn the adjustment screw marked PILOT

clockwise to decrease or counterclockwise to

increase the flame to proper size (see Figure 42,

page 28). Do not remove the adjustment screw.

• see Troubleshooting, page 31

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating.

Flame patterns will be different from unit to unit

and will vary depending on installation type and

weather conditions.

If the vent configuration is installed incorrectly,

the flames will lift or "ghost". This can be danger-

ous. Inspect the flames after installation to ensure

proper installation and performance.

Figure 45 shows a typical flame pattern.

If burner flame pattern differs from that de-

scribed:

• turn fireplace off (see To Turn Off Gas to Ap-

pliance, page 28)

• see Troubleshooting, page 31

Advertising
This manual is related to the following products: