Troubleshooting, Cleaning and maintenance – Desa (V)KC36NE Series User Manual

Page 31

Advertising
background image

www.desatech.com

116238-01E

31

VENTING SYSTEM

Conduct annual inspection of the venting system

following these guidelines:

1. Check areas of venting system that are ex-

posed to the weather for corrosion (rust spots

or streaks and, in extreme cases, holes). Have

these items replaced immediately by a quali-

fied service person.

CLEANING AND

MAINTENANCE

Continued

2. Remove the vent cap and shine a flashlight

into the vent. Remove any foreign material.

3. Check for evidence of excessive condensation.

Continuous condensation can cause corrosion

of caps, pipes and fittings and can be caused

by having excessive lateral runs, too many

elbows or exterior portions of the system being

exposed to cold weather.

4. Inspect joints to verify that no pipe section or fitting

has been disturbed and loosened. Check mechani-

cal supports such as wall straps for rigidity.

TROUbLEShOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

pilot. This can damage pilot unit.

Note

: Before troubleshooting the system, make sure the gas shutoff valve is ON.

The two most common causes of a malfunctioning gas appliance are:

1. Loose wiring connections

2. Construction debris clogging the pilot and/or gas control valve filter

POSSIBLE CAUSE

1. No gas supply or shutoff

valve is OFF

2. Air in gas line

3. Construction debris clogging

pilot orifice

4. Low gas pressure

5. Kinked pilot line

6. Control valve is not opening

7. No power to unit or the igni-

tion module or power trans-

former is bad

REMEDY

1. Check to see if you have gas

supply and that equipment

shutoff valve is opened

2. Repeat lighting procedure

several times to purge all air

out of lines. If after repeated

attempts appliance does not

light, call for qualified service

and repair.

3. Remove debris and dirt, in-

spect and clean any other

possible obstructions

4. Contact your gas supplier to

check pressure

5. Have a qualified technician

replace pilot line

6. Replace control valve (Refer to

Replacement Parts, page 34)

7. Check that main power is

on and that all wire connec-

tions are made correctly to

the ignition model (see Wiring

Diagram, page 27). Check for

24 VAC at the secondary side

of the transformer. If 24 VAC

is present and the module does

not operate, have the module

replaced otherwise have the

transformer replaced

OBSERVED PROBLEM

Ignitor will not spark or pilot

will not light

Advertising
This manual is related to the following products: