Revision E

10

July 2012

Dry Contact Alarm (3G+ RM Only)


There are dry contact alarms located on each module in the 3G+ Rack Mount units. When there is
an alarm condition, such as an over temperature condition or an issue with a power supply or fan,
the relay is energized.

Figure 3: Dry Contact Alarm


The dry contact alarm is a Form C contact with the following ratings:

Nominal switching capacity- 1A, 30VDC, 0.3A 125VAX (resistive load)

Max. switching power- 30W (DC), 37.5VA (AC) (resistive load)



If there are no current alarm conditions the front panel should read as below with “0” indicating that
there are no failures:

Figure 4: No Alarm Conditions Present


If an alarm condition is identified, a “1” will indicate a failure as described below:

Figure 5: Alarm Conditions Present


This example indicates that Fan #2 and Power Supply #1 have each encountered a failure.



ALARM

FANS PS TEMP

0000 00 0

ALARM

FANS PS TEMP

0100 01

0