2.3.

Product Overview

2.3.1. Mounting the OriginKVM 8250

You may choose to rack mount your OriginKVM 8250 or place it on a shelf or desktop (feet included).

The front panel display should be visible and front panel buttons accessible. All connections are made

to the rear of the chassis.

2.3.1.1. Rack Mount or Desktop

The OriginKVM 8250 may be installed in an EIA-standard 19 inch rack (1U tall), or placed on a shelf or

desktop. For shelf use, attachable rubber feet are provided and the rack mounted brackets can be easily

removed. The OriginKVM 8250 chassis does not need to be opened or accessed. The sturdy metal

case allows units to be stacked as required.

NOTE

:

Be sure to leave adequate ventilation space on both sides of the units, especially if units

are being stacked. Each rack mount bracket is held on by 4 screws. The brackets may be

positioned so that the unit sits forward or is recessed in your rack. If the brackets are

removed or repositioned, it is not necessary to re-use the left-over rack mount screws.

2.3.2. Front Panel Display and Buttons

The front-panel LCD display should be visible and accessible for system setup. The front panel buttons

are used to configure special video settings and to review existing OriginKVM 8250 configurations.

LCD Navigation Pad

LCD System Information

and Programming

FIGURE 2: OriginKVM 8250 Front Panel LCD Display

2.3.3. Convection Cooled

The OriginKVM 8250 does not require special cooling or ventilation other than what is normally provided

in the equipment rack. No fan means that it does not add to the ambient noise in your equipment room

and it is less prone to equipment failure. Be sure not to block the air vents on the sides of the unit, and

leave space on both sides. If mounted in an enclosed rack, it is recommended that the rack have an

adequate ventilation fan to provide airflow through the unit(s).