17600 – System Data

System data consists of 8 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply 1 alarm, and bit 7
(msb) is the bit for the 'any' alarm. The next two bytes are for the installed card inventory.
A '0' bit means the card is installed and a '1' bit means the card is removed. The other bytes
are for internal use.

17601:17616 – Card Data

Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:

•

15 bytes, internal use

•

1 byte, card type
◦

0xff

missing

◦

0x00

upstream

◦

0x01

downstream

•

SFP data, 256 bytes per SFP, 20 SFPs per card
◦

128 bytes, SFP ID data

◦

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: VX160

11/25

Table 2: VX160 System Data

Alarms

Inventory

Byte

Byte

Byte

Bit

0

1

2

0

Alarm 1

Card 1

Card 9

1

Alarm 2

Card 2

Card 10

2

Alarm 3

Card 3

Card 11

3

Alarm 4

Card 4

Card 12

4

Alarm 5

Card 5

Card 13

5

Alarm 6

Card 6

Card 14

6

Alarm 7

Card 7

Card 15

7

Alarm 8

Card 8

Card 16

Advertising