17600 – system data, 17601:17616 – card data – Thinklogical Router Interfaces User Manual
Page 11

17600 – System Data
System data consists of 8 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply 1 alarm, and bit 7
(msb) is the bit for the 'any' alarm. The next two bytes are for the installed card inventory.
A '0' bit means the card is installed and a '1' bit means the card is removed. The other bytes
are for internal use.
17601:17616 – Card Data
Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:
•
15 bytes, internal use
•
1 byte, card type
◦
0xff
missing
◦
0x00
upstream
◦
0x01
downstream
•
SFP data, 256 bytes per SFP, 20 SFPs per card
◦
128 bytes, SFP ID data
◦
128 bytes, SFP diagnostic data
Nov 3, 2014
Router Interfaces: VX160
11/25
Table 2: VX160 System Data
Alarms
Inventory
Byte
Byte
Byte
Bit
0
1
2
0
Alarm 1
Card 1
Card 9
1
Alarm 2
Card 2
Card 10
2
Alarm 3
Card 3
Card 11
3
Alarm 4
Card 4
Card 12
4
Alarm 5
Card 5
Card 13
5
Alarm 6
Card 6
Card 14
6
Alarm 7
Card 7
Card 15
7
Alarm 8
Card 8
Card 16