17600 – System Data

System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 of byte 1 is the bit for the
Power Supply 1 alarm, and bit 1 of byte 0 is the bit for the 'any' alarm. The next five bytes
are for the installed card inventory. A '0' bit means the card is installed and a '1' bit means
the card is removed. The other bytes are for internal use.

17601:17640 – Card Data

Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:

•

12 bytes, internal use

•

1 byte, card type
◦

0xff

missing

◦

0x02

installed

•

SFP data, 256 bytes per SFP, 16 SFPs per card
◦

128 bytes, SFP ID data

◦

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: VX320

13/25

Table 3: Vx320 System Data

Alarms

Inventory

Byte

Byte

Byte

Byte

Byte

Byte

Byte

Bit

0

1

2

3

4

5

6

0

Alarm 9

Alarm 1

Upper Card 1

Upper Card 9

Upper Card 17 Lower Card 5

Lower Card 13

1

Alarm 10

Alarm 2

Upper Card 2

Upper Card 10 Upper Card 18 Lower Card 6

Lower Card 14

2

Alarm 3

Upper Card 3

Upper Card 11 Upper Card 19 Lower Card 7

Lower Card 15

3

Alarm 4

Upper Card 4

Upper Card 12 Upper Card 20 Lower Card 8

Lower Card 16

4

Alarm 5

Upper Card 5

Upper Card 13 Lower Card 1

Lower Card 9

Lower Card 17

5

Alarm 6

Upper Card 6

Upper Card 14 Lower Card 2

Lower Card 10 Lower Card 18

6

Alarm 7

Upper Card 7

Upper Card 15 Lower Card 3

Lower Card 11 Lower Card 19

7

Alarm 8

Upper Card 8

Upper Card 16 Lower Card 4

Lower Card 12 Lower Card 20

Advertising