17600 – system data, 17601:17603 – card data – Thinklogical Router Interfaces User Manual
Page 19

17600 – System Data
System data consists of 6 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply alarm, and bit 3 is
the bit for the 'any' alarm. The next byte is for the installed card inventory. A '0' bit means
the card is installed and a '1' bit means the card is removed. The other bytes are for
internal use.
17601:17603 – Card Data
Each I/O card in the router has an associated TCP port. Card 1 uses port 17601, card 2 uses
17602, and so on. The data is formatted as follows:
•
6 bytes, internal use
•
1 byte, card type
◦
0xff
missing
◦
0x02
normal
◦
0x05
reclocked
•
SFP data, 256 bytes per SFP, 16 SFPs per card
◦
128 bytes, SFP ID data
◦
128 bytes, SFP diagnostic data
Nov 3, 2014
Router Interfaces: MX48
19/25
Table 6: MX48 System Data
Alarms
Inventory
Byte
Byte
Bit
0
1
0
Alarm 1
Card 1
1
Alarm 2
Card 2
2
Alarm 3
Card 3
3
Alarm 4
4
5
6
7