17600 – System Data

System data consists of 6 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply alarm, and bit 3 is
the bit for the 'any' alarm. The next byte is for the installed card inventory. A '0' bit means
the card is installed and a '1' bit means the card is removed. The other bytes are for
internal use.

17601:17603 – Card Data

Each I/O card in the router has an associated TCP port. Card 1 uses port 17601, card 2 uses
17602, and so on. The data is formatted as follows:

•

6 bytes, internal use

•

1 byte, card type
◦

0xff

missing

◦

0x02

normal

◦

0x05

reclocked

•

SFP data, 256 bytes per SFP, 16 SFPs per card
◦

128 bytes, SFP ID data

◦

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: MX48

19/25

Table 6: MX48 System Data

Alarms

Inventory

Byte

Byte

Bit

0

1

0

Alarm 1

Card 1

1

Alarm 2

Card 2

2

Alarm 3

Card 3

3

Alarm 4

4

5

6
7