17600 – system data, 17601:17620 – card data – Thinklogical Router Interfaces User Manual

Page 15

Advertising
background image

17600 – System Data

System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 (lsb) of byte 1 is the bit for
the Power Supply 1 alarm, and bit 7 (msb) is the bit for the 'any' alarm. The next three
bytes are for the installed card inventory. A '0' bit means the card is installed and a '1' bit
means the card is removed. The other bytes are for internal use.

17601:17620 – Card Data

Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:

•

12 bytes, internal use

•

1 byte, card type
◦

0xff

missing

◦

0x01

downstream

•

SFP data, 256 bytes per SFP, 16 SFPs per card
◦

128 bytes, SFP ID data

◦

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: VX320Video

15/25

Table 4: Vx320Video System Data

Alarms

Inventory

Byte

Byte

Byte

Byte

Byte

Bit

0

1

2

3

4

0

Alarm 1

Card 1

Card 9

Card 17

1

Alarm 2

Card 2

Card 10

Card 18

2

Alarm 3

Card 3

Card 11

Card 19

3

Alarm 4

Card 4

Card 12

Card 20

4

Alarm 5

Card 5

Card 13

5

Alarm 6

Card 6

Card 14

6

Alarm 7

Card 7

Card 15

7

Alarm 8

Card 8

Card 16