17600 – System Data

•

System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 (lsb) of byte 1 is the bit for
the Power Supply 1 alarm, and bit 7 (msb) is the bit for the 'any' alarm. The next five bytes
are for the installed card inventory. A '0' bit means the card is installed and a '1' bit means
the card is removed. The other bytes are for internal use.

17601:17636 – Card Data

•

Each I/O card in the HDxRouter has an associated TCP port. Card 1 uses port 17601, card
2 uses 17602, and so on. The data is formatted as follows:

•

12 bytes, internal use

•

1 byte, card type
◦

0xff missing

◦

0x01 downstream

•

SFP data, 256 bytes per SFP, 16 SFPs per card
◦

128 bytes, SFP ID data

◦

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: HX576

17/25

Table 5: Hx576 System Data

Alarms

Inventory

Byte

Byte

Byte

Byte

Byte

Byte

Byte

Bit

0

1

2

3

4

5

6

0

Alarm 9

Alarm 1

Card 1

Card 9

Card 26

Card 14

Card 31

1

Alarm 10

Alarm 2

Card 2

Card 19

Card 27

Card 15

Card 32

2

Alarm 3

Card 3

Card 20

Card 16

Card 33

3

Alarm 4

Card 4

Card 21

Crad 17

Card 34

4

Alarm 5

Card 5

Card 22

Card 10

Card 18

Card 35

5

Alarm 6

Card 6

Card 23

Card 11

Card 28

Card 36

6

Alarm 7

Card 7

Card 24

Card 12

Card 29

7

Alarm 8

Card 8

Card 25

Card 13

Card 30

Advertising