Tri Tool 236B Single Point User Manual
Page 12
12
TRI TOOL INC.
92-1333 : Rev. 110404
NOTE:
Tool Bit Clearance
Final Prep Location
Pipe
Clearance
Jaw Block
Feed
Handle
Plate
Attach the proper power supply line to the drive assembly. If using a pneu-
matic drive assembly, use an adequate in-line filter, regulator, and lubrica-
tor (FRL).
The Tri Tool Air Caddy, a portable combination filter, regulator, and lubricator
(FRL) unit is recommended.
Turn the motor on.
Let the machine rotate very slowly for one revolution to verify that the tool bit clears
the OD of the pipe.
Adjust the cutting speed by opening the Flow Control Valve at the power supply
connection.
The actual machining operation will begin when the tool bit contacts the pipe.
If the pipe end is not square with the pipe axis, the tool bit will contact only a
small segment of the pipe during each revolution.