Tri Tool 236B Single Point User Manual

Page 23

Advertising
background image

23

Model 236B Single Point

92-1333 : Rev. 110404

Problem:

There's a Loss of Air Power

The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.

Problem:

There's a Loss of Hydraulic Power

The hydraulic supply pressure is too low.
The hydraulic filter is plugged.
The hydraulic line size is insufficient.
The hydraulic line is too long.

Problem:

The Tool Bit Will Not Reach the Work

Incorrect tool blocks are installed for the size of the pipe or tube being
worked on.
Incorrect tool bit is installed.

Problem:

The Air Motor Will Not Start

The air power supply is shut off.
The air motor is damaged and will not run free.
The air motor needs lubrication.
Add lubrication and do not run the air motor for a few minutes, then try run-
ning the motor.
Tap on the side of the air motor casing lightly with a piece of wood or with a
soft rubber mallet just in case the vanes may be sticking.
Sand or other foreign material may be in the vanes of the air motor.

Problem:

The Hydraulic Motor Will Not Start

The hydraulic power supply is shut off.
The hydraulic motor is damaged and will not run free.