Installation – Desa CDR3924NT User Manual

Page 12

Advertising
background image

www.desatech.com

113183-01D

12

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

CAUTION: For propane/LP

gas, never connect heater di-

rectly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between the

heater and propane/LP supply.

Installation Items Needed
Before installing heater, make sure you have the

items listed below.
• external regulator for propane/LP only (sup-

plied by installer)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 25.
For propane/LP only, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down

as shown in Figure 12. Pointing the vent down

protects it from freezing rain or sleet.

WARNING: For natural

gas, never connect heater to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" inside diameter or greater

to allow proper gas volume to

heater. If pipe is too small, undue

loss of volume will occur.

Installation must include an equipment shutoff

valve, union and plugged 1/8" NPT tap. Locate

NPT tap within reach for test gauge hook up. NPT

tap must be upstream from heater (see Figure 13,

page 13).
IMPORTANT:

Install equipment shutoff valve

in an accessible location. The equipment shutoff

valve is for turning on or shutting off the gas to

the appliance.
Check building codes for any special require-

ments for locating equipment shutoff valve to

fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

Propane/LP
Supply Tank

External
Regulator

Figure 12 - External Regulator With Vent

Pointing Down

Vent
Pointing
Down

Advertising