Product identification, Unpacking, Product features – Desa CDR3924NT User Manual

Page 5: Air for combustion and ventilation

Advertising
background image

www.desatech.com

5

113183-01D

PRODUCT

IDENTIFICATION

Log Set

Base
Assembly

Ignitor

Burner
Control Knob

Figure 1 - Product Identification

Grate

UNPACKING

CAUTION: Do not remove

the data plates from the base as-

sembly. The data plates contain

important warranty and safety

information.

1. Remove logs and heater base assembly from

carton. Note: Do not pick up heater base as-

sembly by burners. This could damage heater.

Always handle base assembly by the sides of

assembly.

2. Remove all protective packaging applied to

logs and heater for shipment.

3. Check all items for any shipping damage. If

damaged, promptly inform dealer where you

bought heater.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside

venting. There is no heat loss out a vent or up a

chimney. Heat is generated by both realistic flames

and glowing coals. This heater is designed for vent-

free operation with flue damper closed. It has been

tested and approved to ANSI Z21.11.2 standard for

unvented heaters. State and local codes in some

areas prohibit the use of vent-free heaters.

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS/pilot is a required feature for vent-free room

heaters. The ODS/pilot shuts off the heater if there

is not enough fresh air.

IGNITION SYSTEM

This heater has an electronic ignitor to light heater

fuel supply.

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall

not be installed in a confined

space or unusually tight construc-

tion unless provisions are provid-

ed for adequate combustion and

ventilation air. Read the following

instructions to insure proper fresh

air for this and other fuel-burning

appliances in your home.

Todayʼs homes are built more energy efficient

than ever. New materials, increased insulation and

new construction methods help reduce heat loss

in homes. Home owners weather strip and caulk

around windows and doors to keep the cold air out

and the warm air in. During heating months, home

owners want their homes as airtight as possible.
While it is good to make your home energy effi-

cient, your home needs to breathe. Fresh air must

enter your home. All fuel-burning appliances need

fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel

burning appliances draw air from the house to

operate. You must provide adequate fresh air for

these appliances. This will insure proper venting

of vented fuel-burning appliances.

PROVIDING ADEQUATE
VENTILATION

The following are excerpts from National Fuel

Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,

Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol-

lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help

you classify your space and provide adequate

ventilation.

Advertising