POSSIBLE CAUSE

1. Control knob not fully pressed in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered

4. Equipment shutoff valve not

fully open

5. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

6. Thermocouple connection

loose at control valve

7. Thermocouple damaged

8. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

1. Manifold pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30

seconds

3. Wait one minute for safety

interlock system to reset.

Repeat ignition operation

4. Fully open equipment shutoff

valve

5. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance

,

page 19) or replace ODS/pilot

assembly

6. Hand tighten until snug, then

tighten 1/4 turn more

7. Replace pilot assembly

8. Replace control valve

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 19) or

replace burner orifice(s)

3. Contact qualified service

person

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 19) or

replace burner orifice(s)

3. Contact qualified service

person

1. Clean burner (see Cleaning

and Maintenance, page 19)

or replace burner orifice

2. Replace damaged burner

3. Replace gas regulator

1. Check burner(s) for dirt

and debris. If found, clean

burner(s) (see Cleaning and

Maintenance, page 19)

2. Replace gas regulator

OBSERVED PROBLEM

ODS/pilot lights but flame

goes out when control knob is

released

One or more burners do not light

after ODS/pilot is lit

Delayed ignition of one or more

burners

Burner backfiring during com-

bustion

Yellow flame in burner during

burner combustion