Alarms Screen

The Alarms screen (Figure 3-3) is used to view the current alarm status of the
network and the DTE lines. The fields are described as follows.

Figure 3-3 Alarms Screen

DTE Alarms

This status line displays the selected elements current DTE signal alarm state. The
Alarm State for the Dual DSX port is shown on the DTE Alarms Status Line as
XY, where X is the slot and Y is the port, for example, 3A. DTE Alarm can be
enabled or disabled in the Dual DSX Configuration Screen (Figure 3-13 on page
13
) at the Alarm on LOS/OOF parameter.

(alarm status)

The main body of the Alarms screen shows the current count for parameters used
to trigger an alarm.

The Current column shows the total of the preceding 15 one- minute intervals. At
the end of each one-minute interval, the oldest minute of the 15 -minute interval is
discarded.

The Threshold column shows the values set in the Alarm screen. Any parameter
that has a current value equal to or greater than its non-zero threshold generates an
alarm. Any parameter with a threshold value of 0 is disabled from generating
alarms.

The DTE LOS/OOF seconds field does not apply to the Dual DSX card.

The parameters shown on the Alarms Screen are updated at five-second intervals.

Power Loss

Seconds

Displays the number of seconds that the element has been without power since this
value was last cleared.

Reset Alarm

Registers

Pressing Enter on (RESET) clears all Current alarm parameters, but does not
change 24 -hour or 30- day performance registers.

3030 DSU x.xx/x.xx

PRISM 3030 Date:

MM/DD/YY

No Far End Response

(Unit Address: 23)

Time: HH:MM:SS

----------------------------------- ALARMS

-------------------------------------

NET Alarms: OK
DTE Alarms: OK

Current

Threshold

Loss of Signal Seconds (LOSS)

0

5

Errored Seconds (ES)

2

45

Severely Errored Seconds (SES)

2

5

Unavailable Seconds (UAS)

0

0

Out of Frame Seconds (OOFS)

0

5

Remote Alarm Seconds (RAS)

0

0

AIS Seconds (AISS)

0

0

BPV Seconds (BPVS)

0

0

DTE LOS/OOF Seconds (LOSS)

0

0

Power Loss Seconds (PLS)

0

Reset Alarm Registers:

(RESET)