Portloop, Dsx port loop, Bert – Verilink PRISM 3010 Dual DSX-1 (34-00250.2) Product Manual User Manual

Page 18: Pattern, Test length, Port loop dsx port loop, Bert pattern

Advertising
background image

12

C

HAPTER

3: T

ERMINAL

O

PERATION

Port Loop

Used to loop a high-speed DTE at the near or far end. High-speed port loops are
bidirectional.

Figure 3-11 Port Loop

DSX Port Loop

Used to loop the data from the customer equipment back to the customer. The data
from the network is terminated and the data from the customer is passed through
to the network.

Figure 3-12 DSX Port Loop

BERT

BERT

Specifies the direction the BERT signal is sent. If the direction is changed from the
front panel, the new choice is not updated on the terminal interface until this
screen is exited and then reentered. The choices are: IDLE, T1 NET, T1 DTE,
Channels 1 –24, plus X Y NET and X Y DTE, where X = 2 or 3 in the PRISM
3030 or 2 through 6 in the PRISM 3060 and Y = A or B.

All testing must be stopped before channels can be reallocated to an active port.

Pattern

Specifies the pattern transmitted during a test. Modifying this field does not cause
the pattern to be transmitted (see Start Test below). The choices are QRSS, 63,
511, 2047, 2

15

, 2

20

, 2

23

, 1:8, 3:24, ALT, and CLEAR. The CLEAR pattern passes

the received data through the unit (alarm detection and reporting is disabled while
the test is active).

Test Length.

Defines the run -time of test pattern generation and error

accumulation. The choices are Continuous, 15 min, 30 min, 60 min, and 24 Hour.

Network Interface

Framer/Deframer

Multiplexer

Receivers/Drivers

Receivers/Drivers

BERT Generator /

Detector

EIA-530 or V.35

(100' max.)

Framer /Deframer

DTE (DSX1)

RJ-48C

DSX1, 1'-655'

to cross-connect

To

NET

From

NET

From

NET

To

NET

5

4

2

1

To Network

From Network

RJ-48C

5

4

2

1

To

Ports

From

Ports

DTE

Near/Far

Network Interface

Framer/Deframer

Multiplexer

Receivers/Drivers

Receivers/Drivers

BERT Generator /

Detector

Dual DSX port

Framer /Deframer

DTE (DSX1)

RJ-48C

DSX1, 1'-655'

to cross-connect

From

NET

To

NET

From

NET

To

NET

5

4

2

1

To Network

From Network

RJ-48C

5

4

2

1

To

Ports

From

Ports

DTE

Near/Far

Advertising