Timing source, Figure 2-2 top-edge view of the prism4001, Table 2-a timing source – Verilink PRISM 4001 (34-00244) Product Manual User Manual

Page 12: Dds network rate, Table 2-b dds network rate, Dte line rate, Table 2-c dte line rate = 56 kbps, txport mode, Table 2-d dte line rate = 64 kbps, txport mode, Table 2-e dte rate=56 or 64 kbps, txport mode, a

Advertising
background image

2-2 Installation

PRISM 4001

T

IMING

S

OURCE

Positions S1-1 and S1-2 determine the source of unit clock-
ing. The most common timing source for most DDS appli-
cations is to derive timing from the network. The unit may
also be clocked from an internal standard or from the DTE
as shown in Table 2 -A.

DDS N

ETWORK

R

ATE

Positions S1-2 through S1-5 are used to set the network
interface line rate as shown in Table 2-B.

DTE L

INE

R

ATE

Positions S1-6 through S1-8 are used to set the DTE inter-
face line rate as shown in Table 2-C. If in TxPORT mode
and Sync mode and Line Rate is 56 kbps, then:

If in TxPORT mode, Sync format, and the Line Rate is 64
kbps, set the DTE Line Rate as shown in Table 2-D.

If in TxPORT mode, with a Line Rate of 56 or 64 kbps, and
in ASYNC format, set the DTE rate as shown in Table 2-E.

In TxPORT mode, if the DDS Network Rate is
less than 56 kbps. The DTE Rate must match the
Net Rate. The Sync format is not allowed in
TxPORT mode below 56 kbps.

Table 2-A Timing Source

Timing

Source

S1-1

S1-2

Network

Down

Down

DTE

Down

Up

Internal

Up

Down

Table 2-B DDS Network Rate

Network

Rate

S1-3

S1-4

S1-5

56 kbps

Down

Down

Down

64 kbps

Down

Down

Up

2.4 kbps

Down

Up

Down

4.8 kbps

Down

Up

Up

9.6 kbps

Up

Down

Down

19.2 kbps

Up

Down

Up

38.4 kbps

Up

Up

Down

Table 2-C DTE Line Rate = 56 kbps, TxPORT

Mode, and Sync Mode

DTE Rate

S1-6

S1-7

S1-8

54 kbps

Down

Down

Down

2.4 kbps

Down

Down

Up

4.8 kbps

Down

Up

Down

9.6 kbps

Down

Up

Up

19.2 kbps

Up

Down

Down

38.4 kbps

Up

Down

Up

Figure 2 -2 T

OP

-E

DGE

V

IEW

OF

THE

P

RISM

4001

Switch S1

1

8

7

6

5

4

3

2

Switch S2

1

8

7

6

5

4

3

2

Switch S3

1

8

7

6

5

4

3

2

Switch S4

1

8

7

6

5

4

3

2

RS232 -----V.35

RS232 -----V.35

Table 2-D DTE Line Rate = 64 kbps, TxPORT

Mode, and Sync Mode

DTE

Rate

S1-6

S1-7

S1-8

62 kbps

Down

Down

Down

56 kbps

Down

Down

Up

2.4 kbps

Down

Up

Down

4.8 kbps

Down

Up

Up

9.6 kbps

Up

Down

Down

19.2 kbps

Up

Down

Up

38.4 kbps

Up

Up

Down

Table 2 -E DTE Rate=56 or 64 kbps, TxPORT Mode,

and Async Mode

DTE Rate

S1-6

S1-7

S1-8

57.6 kbps

Down

Down

Down

2.4 kbps

Down

Down

Up

4.8 kbps

Down

Up

Down

9.6 kbps

Down

Up

Up

19.2 kbps

Up

Down

Down

38.4 kbps

Up

Down

Up