Boot mode, Table 2-n boot mode, Configuration switch s3 – Verilink PRISM 4001 (34-00244) Product Manual User Manual

Page 14: Figure 2-4 switch s3, Nms rate, Table 2-o nms rate, Supv port rate, Table 2-p supv rate, Dial backup, Table 2-q dial backup

Advertising
background image

2-4 Installation

PRISM 4001

B

OOT

M

ODE

Positions S2-7 and S2-8 select the startup boot configura-
tion method as shown in Table 2-N.

Configuration Switch S3

Switch S3 (Figure 2-4) sets the configuration parameters
listed in the following paragraphs.

NMS R

ATE

Positions S3-1 and S3-2 set the bit rate for the network
management system as shown in Table 2-O.

SUPV P

ORT

R

ATE

Positions S3-3 and S3-4 set the supervisory port rate as
shown in Table 2- P.

D

IAL

B

ACKUP

Position S3-5 can enable the unit’s dial backup feature as
shown in Table 2-Q.

DBU R

ATE

Positions S3-6 through S3-8 set the DBU port rate as shown
in Table 2-R.

Address Switch S4

Switch S4 sets the unit address. When using the 4001 with a
8100A Site Controller, each element in a group must have a
unique unit address. As many as 50 units (with addresses from
1 to 50) can exist in a group. If the unit is not connected to a
site controller, the NMS unit address should be left at the fac-
tory default setting of 1 where Position 1 is Up and all other
positions are Down (see Figure 2-5).

Switch S4 has eight positions used to create an 8-bit binary
code for an address in the range of 1 to 50. Switch position S4-
1is the least significant bit (LSB) and S4-8 is the most signifi-
cant bit (MSB). If a switch is down, its value is 0. If up, its
value is that of the upper location. the values are additive. For
example, to set a unit address to 5, position S4-3 (binary value
is 4) and position S4-1 (binary value is 1 would be set Up for a
unit address of 5 (4+1). All other positions would be set Down.

Interface Switches S5 and S6

Switches S5 and S6 are slide switches that set the unit to
either RS-232 or V.35. Both switches must be set to the
same selection (that is, RS-232 or V.35).

Table 2 -N Boot Mode

Power-up Mode

S2-7

S2-8

Boot from SAVED

Down

Down

Boot from DEFAULT

Down

Up

Boot from SWITCHED

Up

Down

Boot from CONTROLLER

Up

Up

Table 2-O NMS Rate

NMS Rate

S3-1

S3-2

19.2 kbps

Down

Down

1.2 kbps

Down

Up

2.4 kbps

Up

Down

9.6 kbps

Up

Up

Table 2-P SUPV Rate

SUPV Rate

S3-3

S3-4

19.2 kbps

Down

Down

1.2 kbps

Down

Up

2.4 kbps

Up

Down

9.6 kbps

Up

Up

7

6

5

4

3

2

1

8

NM

S

NM

S

SU

P

V

DB

U

DB

U

Rate

Rate

Rate

Rate

DB

U

Rate

Rate

SU

P

V

Rate

Switch

S3

DB

U

En

ab

le

Figure 2 -4 Switch S3

Do

wn

Up

Table 2-Q Dial Backup

Dial Backup

S3-5

Disabled

Down

Enabled

Up

Table 2-R DBU Rate

DBU Rate

S3-6

S3-7

S3-8

57.6 kbps

Down

Down

Down

2.4 kbps

Down

Down

Up

4.8 kbps

Down

Up

Down

9.6 kbps

Down

Up

Up

19.2 kbps

Up

Down

Down

38.4 kbps

Up

Down

Up

7

6

5

4

3

2

1

8

LSB

MSB

Binary values

D

o

w

n

U

p

1

2

4

8

16

32

64 128

0

0

0

0

0

0

0

0

Switch

S4

Figure 2 -5 Switch S4

Advertising