background image

Terminal Operation 4-3

PRISM 4001

If no key is pressed for ten minutes, the terminal
interface logs off automatically. To manually log
off, press ESCAPE from the Main Menu.

Alarms Screen

The Alarms screen (Figure 4-3) displays the current alarm
status of the network and the DTE lines. The fields are
described as follows:

NET

AND

DTE A

LARMS

The status lines shown in Table 4-B display the selected ele-
ment’s current network /DTE signal alarm state. Alarms are
determined by the following user-selectable thresholds:

A

LARM

S

TATUS

The main body of the Alarms screen shows the current
count for parameters that may be used to trigger an alarm.

The Current column shows the total of errored seconds for
each alarm type. The Threshold column shows the values
set in the Alarm Configuration screen (Figure 4-13). Any
parameter that has a current value equal to or greater than its
non-zero threshold generates an alarm. Any parameter with
a threshold value of 0 is disabled from generating alarms.

The parameters shown on the Alarms Screen are
updated at five-second intervals.

R

ESET

A

LARM

R

EGISTERS

Pressing ENTER on (RESET) zeros the value of all Current
alarm parameters.

Table 4-B Alarm Indications

Message

Meaning

none

No alarm threshold has been exceeded, although
errors may exist which do not exceed thresholds.

OOS

The Out Of Service Seconds threshold is exceeded.

LOS

The Loss Of Signal Seconds threshold is exceeded.

OOF

The Out Of Frame Seconds threshold is exceeded.

DBA

Dial Backup is active.

DBF

Dial Backup failed.

DTR

The DTR port sees the DTR signal as low.

4001 DSU x.xx/x.xx

PRISM 4001 Local

Screen

4001 DSU x.xx/x.xx

Unit Address: X

------------------------------- ALARMS

---------------------------------

Element: [NEAR]

NET Alarms: LOSS

DTE Alarms: NONE

Current

Threshold

Loss of Signal Seconds (LOSS)

348

5

Out of Service Seconds (OOSS)

482

0

Out of Frame Seconds (OOFS)

0

0

Reset Alarm Registers: (RESET)

Figure 4-3 Alarms

Advertising