14. SAT III Controller Installation Guide

WCC III Technical Guide

14-24

SAT III Binary Input Wiring

8

7

SAT ADDRESS

2

1

4

8

A 3 WIRE ROOM SENSOR WILL NOT
REQUIRE A LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

WattMaster Controls Inc.

BINARY
INPUTS

BINARY
INPUTS

L8

ON OFF

128

32
16

64

L4
L3
L2

L1

L6
L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14

L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF
PULSE INPUT

OPTION 1

TEST

OPTION 3
OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

A 2 WIRE ROOM SENSOR WILL REQUIRE
A 300 OHM LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

A 4 TO 20 mA SENSOR WILL REQUIRE A
50 OHM LOAD RESISTOR WHEN SET FOR
A 1 VOLT INPUT, OR A 250 OHM LOAD
RESISTOR WHEN SET FOR A 5 VOLT INPUT.

CURRENT
INPUT

THERMISTOR
INPUT

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

0 - 10V

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

PROGRAMMABLE CONTROLLER

SAT III

A25

0

VA

C

~

5A

30

V

D

C

SA

VDE

G5

Q

-1

A

4

OM

R

O

N

1

2

3

4

5

6

1

2

3

4

5

6

+V SENSORS

R1

R2

1

2

R3

R4

R5

R6

3

4

5

6

C

7

8

C

H

VO

U

T

GN

D

7

8

R

R7

R8

7

8

AT

K1
6

K1
5

K1
4

K1
3

V16

V15

V14

V13

COMM

GND

GND

BIN8

BIN7

BIN6

BIN5

BIN4

BIN3

BIN2

BIN1

BIN1

BIN2

BIN3

BIN4

BIN5

BIN6

BIN7

BIN8

MADE IN USA

SERIAL #

15 MIN

30 MIN
1 HR

2 HRS

3 HRS

4 HRS
L1-8
L9-16

TIME DELAY

HSS

HSS

EEPROM

485 DRV

POWER

PROGRAM SOCKET

STAT

CHASSIS GND

U14

C16

C15

R48

X1

V1

U13

U1
2

U11

U9

U7

U6

U4

U3

U2

U1

TB1

SW1

R47

R46
R45

R44

R43

R42

R41

R40

R39

R38

R37

R36

R35

R34

R33

R32

R31

R30

R29

R28

R27

R26

R25

R24

R23

R22

R21

R20

R19

R18

R17

R16

R15

R14

R13

R12

R11

R10

R9

R8

R7

R6

R5

R4

R3

R2

R1

P3

P2

P1

J1

D11

D2

D1

C14

C11

C10

C9

C8

C7

C6

C5

C4

C3

C2

C1

U5

U8

C17

P4

R49

D13

R50

R51

R52

R53

R54

R55

R56

R57

WCC3 BINARY IN W/ TIME DELAY

WATTMASTER CONTROLS, INC

YS102072 REV 2

P

S

2

505

100

2

100

2

100

2

100

2

100

2

100

2

100

2

3300

1211

3831

10
0p
F

22pF

22pF

93
C

4

6

1

0uF

1

0uF

10uF

1001

1001

1001

1001

1001

1001

1001

1001

1000

1000

4701

3650

365

0

365

0

10
u

F

.0

1

u

F

100

1

100

1

100

1

100

1

100

1

100

1

100

1

100

1

74HC541

3650

LP2

95

0

-3.3

3650

3650

3650

3650

3650

3650

3650

D1
2

24V

24VAC

120VAC

TO OTHER
SAT III OR TO
WCC III - MCD
WIRE "T" TO "T"
"R" TO "R"
"SHD" TO "SHD"

TO OTHER
SAT III OR TO
WCC III - MCD

BUTT SPLICE POWER
OBSERVE POLARITY

CONNECTION FROM A SAT III CONTROLLER TO A WCC3 BINARY INPUT W/TIME DELAY BOARD.

USING THE "OLD" RIBBON CABLE CONNECTION METHOD AND USING THE SUPPLIED PC-01 CABLE.

24
VA

C

GN

D

PIN #1

PIN #1

RED WIRE - 24VAC

BROWN WIRE - GND

STR

IP

E

IS

PI

N

#1

CONTACT CLOSURE TO GND
ONLY

SAT III CONTROLLER

COMM

GND

GND

BIN8

BIN7

BIN6

BIN5

BIN4

BIN3

BIN2

BIN1

BIN1

BIN2

BIN3

BIN4

BIN5

BIN6

BIN7

BIN8

MADE IN USA

SERIAL #

15 MIN

30 MIN
1 HR

2 HRS

3 HRS

4 HRS
L1-8

L9-16

TIME DELAY

HSS

HSS

EEPROM

485 DRV

POWER

PROGRAM SOCKET

STAT

CHASSIS GND

U14

C16

C15

R48

X1

V1

U13

U1
2

U11

U9

U7

U6

U4

U3

U2

U1

TB1

SW1

R47

R46
R45

R44

R43

R42

R41

R40

R39

R38

R37

R36

R35

R34

R33

R32

R31

R30

R29

R28

R27

R26

R25

R24

R23

R22

R21

R20

R19

R18

R17

R16

R15

R14

R13

R12

R11

R10

R9

R8

R7

R6

R5

R4

R3

R2

R1

P3

P2

P1

J1

D11

D2

D1

C14

C11

C10

C9

C8

C7

C6

C5

C4

C3

C2

C1

U5

U8

C17

P4

R49

D13

R50

R51

R52

R53

R54

R55

R56

R57

WCC3 BINARY IN W/ TIME DELAY

WATTMASTER CONTROLS, INC

YS102072 REV 2

PS2

5

0

5

100

2

100

2

100

2

100

2

100

2

100

2

100

2

3300

1211

3831

10
0p
F

22pF

22pF

93
C

4

6

10
u

F

10
u

F

10uF

1001

1001

1001

1001

1001

1001

1001

1001

1000

1000

4701

3650

365

0

365

0

10
u

F

.0

1

u

F

100

1

100

1

100

1

100

1

100

1

100

1

100

1

100

1

74HC541

3650

LP2

95

0

-3.3

3650

3650

3650

3650

3650

3650

3650

D1
2

24VAC

120VAC

TO OTHER
SAT II OR TO
THE WCC II
COMPUTER

BUTT SPLICE POWER
OBSERVE POLARITY

CONNECTION FROM A SAT II CONTROLLER TO WCC3 BINARY INPUT W/TIME DELAY BOARD.
USING THE "OLD" RIBBON CABLE CONNECTION METHOD AND USING THE SUPPLIED PC-01 CABLE.

24
VA

C

GN

D

REPLACE THE DIP SWITCH IN THE
SAT II CONTROLLER’S COVER WITH
THE RIBBON CABLE.
OBSERVE POLARITY OF PIN # 1
CONNECT PIN 1 TO PIN 1 AS SHOWN

PIN #1

RED WIRE - 24VAC

BROWN WIRE - GND

ST

R

IP

E

IS

PIN

#1

CONTACT CLOSURE TO GND
ONLY

8

SAT

2

1

4

BINARY

INPUTS

BINARY

INPUTS

L8

ON OFF

128
32

16

64

L4

L3

L2

L1

L6

L5

L7

L11

L12

ON OFF

L10

L9

ON OFF

L15

L16
L14

L13

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF

PULSE INPUT

TEST

ON OFF

SAT II

H

C

COM

CHANNEL

2

1

3 4

2

1

3 4

5 6 7 8

5 6 7 8

V

OUT

GND

L

O

A

D

+V

ATI

1

2

3

4

5

6

1

2

3

4

5

6

+V SENSORS

1

2

3

4

5

6

C

7

8

C

H

VO

U

T

GN

D

7

8

R

7

8

AT

EACH CONTACT

IS RATED FOR

24VAC OR VDC

@ .5 AMP MAX

0-15VDC

OUTPUT

MIN LOAD

IS 1K OHM

RESISTIVE

VDC ONLY

WATTMASTER

CONTROLS GROUP

24 VAC ONLY

POWER CONSUMPTION

15VA / 625mA

NUMBER

POWER ---

CHIPS

CHIPSWITCH

CHIPSWIT

TO OTHER
SAT II OR TO
THE WCC II
COMPUTER

SAT II CONTROLLER

WARNING:

OBSERVE POLARITY

BETWEEN THE SAT II AND THE
BINARY INPUT BOARD - GROUND
CONNECTIONS MUST BE THE SAME.

WARNING:

OBSERVE POLARITY

BETWEEN THE SAT III AND THE
BINARY INPUT BOARD - GROUND
CONNECTIONS MUST BE THE SAME.

WIRE NUT

CABLE IS
WM PART # PC-01

CABLE IS
WM PART # PC-01

120VAC WIRING IS BY OTHERS
THE VA RATING FOR THE SAT III CONTROLLER IS 15VA.
THE VA RATING FOR THE WCC3 BINARY INPUT BOARD IS 5 VA.

120VAC WIRING IS BY OTHERS
THE VA RATING FOR THE SAT II CONTROLLER IS 15VA.
THE VA RATING FOR THE WCC3 BINARY INPUT BOARD IS 5 VA.

DRY INPUT CONTACTS ONLY.
CONTACT CLOSURE TO GROUND
ONLY. NO 24VAC/VDC INPUTS.

REPLACE THE DIP SWITCH IN THE
SAT III CONTROLLER’S COVER WITH
THE RIBBON CABLE.
OBSERVE POLARITY OF PIN # 1
CONNECT PIN 1 TO PIN 1 AS SHOWN.

DRY INPUT CONTACTS ONLY.
CONTACT CLOSURE TO GROUND
ONLY. NO 24VAC/VDC INPUTS.

UP TO TWO WCC3 BINARY INPUT W/TIME
DELAY BOARDS MAY BE WIRED TO THE
SAT II CONTROLLER USING THIS
METHOD. CONNECT THE FIRST WCC3
BINARY INPUT W/TIME DELAY BOARD
TO THE SAT II CONTROLLER’S COVER
MOUNTED L1 TO L8 DIP SWITCH BINARY
INPUTS, AND THE SECOND WCC3
BINARY INPUT W/TIME DELAY BOARD
TO THE SAT II CONTROLLER’S COVER
MOUNTED L9 TO L16 DIP SWITCH
BINARY INPUTS.

UP TO TWO WCC3 BINARY INPUT W/TIME
DELAY BOARDS MAY BE WIRED TO THE
SAT III CONTROLLER USING THIS
METHOD. CONNECT THE FIRST WCC3
BINARY INPUT W/TIME DELAY BOARD
TO THE SAT III CONTROLLER’S COVER
MOUNTED L1 TO L8 DIP SWITCH BINARY
INPUTS, AND THE SECOND WCC3
BINARY INPUT W/TIME DELAY BOARD
TO THE SAT III CONTROLLER’S COVER
MOUNTED L9 TO L16 DIP SWITCH
BINARY INPUTS.

Advertising