Wcciii system overview – WattMaster WCC III part 15 User Manual

Page 8

Advertising
background image

14. SAT III Controller Installation Guide

WCC III Technical Guide

14-6

WCCIII System Overview

OE210
TYPICAL
SPACE
SENSOR
(X8 MAX)

ON/OFF RELAY
PUMPS, LIGHTS,
ETC.

8

7

SAT ADDRESS

2
1

4

8

WattMaster Controls Inc.

BINARY
INPUTS

BINARY

INPUTS

L8

ON OFF

128

32
16

64

L4
L3
L2
L1

L6
L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14
L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF
PULSE INPUT

OPTION 1

TEST

OPTION 3
OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

CURRENT
INPUT

THERMISTOR
INPUT

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

PROGRAMMABLE CONTROLLER

SAT III

H

C

COM

CHANNEL

2

1

3

4

2

1

3

4

5

6 7 8

5

6 7 8

V

OUT

GND

L
O
A
D

+V

ATI

8

7

SAT ADDRESS

2
1

4

8

WattMaster Controls Inc.

BINARY
INPUTS

BINARY

INPUTS

L8

ON OFF

128

32
16

64

L4
L3
L2
L1

L6
L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14
L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF
PULSE INPUT

OPTION 1

TEST

OPTION 3
OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

CURRENT
INPUT

THERMISTOR
INPUT

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

PROGRAMMABLE CONTROLLER

SAT III

H

C

COM

CHANNEL

2

1

3 4

2

1

3

4

5

6 7 8

5

6 7 8

V

OUT

GND

L
O
A
D

+V

ATI

"D" MODE

"C" MODE

"C" MODE ADDRESSING NOTES
"C" MODE SAT III ADDRESSING STARTS
AT ADDRESS 8.

EACH "C" MODE SAT III TAKES UP
8 SAT III LOGICAL ADDRESSES.

A "C" MODE SATIII CAN COMMUNICATE
WITH 8 DEVICES TOTAL.

"D" MODE ADDRESSING NOTES
"D" MODE SAT III ADDRESSING STARTS

AT ADDRESS 4.
EACH "D" MODE SAT III TAKES UP 4

SAT III LOGICAL ADDRESSES.
A "D" MODE SAT III CAN COMMUNICATE

WITH 32 DEVICES TOTAL.

SAT IIICD

Communications Interface

TUC XMIT

ON OFF

ON OFF

SAT ADDRESS

1

STATUS

LOCAL SET

16

4
2

8

64
32

128

LOCAL SET DISABLE

OPTION 2

LOCAL SET

OPTION 1

TEST

BATT ON/ OFF

TUC REC

SAT XMIT

SAT REC

OE320

TUC-2R

OE331

TUC-5R+

W
A
R
M
E
R

C
O
O
L
E
R

OVR

OE213
TYPICAL
SPACE
SENSOR

OE421- SAT III
CONTROLLER

OE454/O 455/OE456

E

SAT 3C/D/F

CONTROLLER

W
A
R
M
E
R

C
O
O
L
E
R

OVR

OE213
TYPICAL
SPACE
SENSOR

WCC II TO WCC III
GLOBAL BRIDGE

WCC III-MCD

SINGLE PULSE
INPUT FROM
POWER METER

UP TO 32 TOTAL
FAN COIL, HEAT PUMP
PD VAV TERMINAL UNITS
PI VAV TERMINAL UNITS
PARALLEL FAN BOX, ETC.

VAV BOX

16 OUTPUTS

PER SAT III

UP TO 60 TOTAL SAT III
OR SAT 3C/D/F/P PER LOOP.
THERE ARE 4 POSSIBLE

SAT III RS485
COMMUNICATIONS LOOPS
(UP TO 239 SAT III MAXIMUM)

TO THE ISP
(INTERNET SERVICE PROVIDER)
CONNECTION TO THE INTERNET
(BY OTHERS)

HIGH SPEED CABLE
MODEM / ROUTER

ETHERNET
CABLE

Optional B-OUT Board

( 8 RELAY OUTS)

(2 PER SAT III)

Optional B-INPUT Board

( 8 BINARY INPUTS)

(2 PER SAT III)

HSS PORT

HEAT PUMP

SAT II

SAT III

PROGRAM SOCKET

ADDRESS

24C128

PCF8583

LT1785

WATTMASTER CONTROLS INC

CONNECTION
TO OLD WCC II
MANCHESTER
COMM LOOP

1

2
4
8

16
32
64

128

ADDRESS

SATIII-P

TEST

LOCAL
L DIS

OPT 1
OPT 2
OPT 3

R

T

24 VAC

GND

OPTIONS

PULSE INPUTS

“P” MODE ADDRESSING NOTES

SAT III ADDRESSING STARTSAT

ADDRESS NUMBER 8.

EACH "P" MODE SAT III TAKES UP

(8) SAT III LOGICAL ADDRESSES.

THERE ARE ONLY (8) USED ACTIVE

INPUTS PER SAT 3P.

ANALOG INPUT #1 (PULSE INPUT #1)

ON EACH SAT III ADDRESS IS ACTIVE.

ALL OTHER INPUTS AND OUTPUTS ON

THE SAT 3P ARE NOT FUNCTIONAL.

TOTAL WIRING FOR EACH INPUT NOT

TO EXCEED 100 FEET.

USE 18 GAUGE TWISTED PAIR WITH

SHIELD FOR EACH PULSE METER

CONNECTION.

CONNECT THE SHIELD WIRE TO GND.

HSS PORT

MULTIPLE PULSE
INPUTS FROM
POWER METERS

OE455-P
SAT 3P
CONTROLLER

PL102224
POWER AND
SWITCHABLE COMM

USUALLY ONE
OR TWO PER
FLOOR

SAT COMM LOOP

SAT COMM LOOP

SAT COMM LOOP

TUC COMM LOOP

B B

PL102224
POWER AND
SWITCHABLE COMM

USUALLY ONE
OR TWO PER
FLOOR

FIBER OPTIC LINES
MAXIMUM OF 2.5 MILES
(USES "ST" CONNECTORS)

BUILDING # 2

8

7

SAT ADDRESS

2
1

4

8

WattMaster Controls Inc.

BINARY
INPUTS

BINARY
INPUTS

L8

ON OFF

128

32
16

64

L4
L3
L2
L1

L6
L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14
L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF
PULSE INPUT

OPTION 1

TEST

OPTION 3
OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

CURRENT
INPUT

THERMISTOR
INPUT

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

PROGRAMMABLE CONTROLLER

SAT III

H

C

COM

CHANNEL

2

1

3

4

2

1

3

4

5

6 7 8

5

6 7 8

V

OUT

GND

L
O
A
D

+V

ATI

OE421- SAT III
CONTROLLER

8

7

SAT ADDRESS

2
1

4

8

WattMaster Controls Inc.

BINARY
INPUTS

BINARY
INPUTS

L8

ON OFF

128

32
16

64

L4
L3
L2
L1

L6
L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14
L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF
PULSE INPUT

OPTION 1

TEST

OPTION 3
OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

CURRENT
INPUT

THERMISTOR
INPUT

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

PROGRAMMABLE CONTROLLER

SAT III

H

C

COM

CHANNEL

2

1

3 4

2

1

3

4

5

6 7 8

5

6 7 8

V

OUT

GND

L
O
A
D

+V

ATI

OE421- SAT III
CONTROLLER

"D" MODE

"C" MODE

"C" MODE ADDRESSING NOTES
"C" MODE SAT III ADDRESSING STARTS

AT ADDRESS 8.
EACH "C" MODE SAT III TAKES UP

8 SAT III LOGICAL ADDRESSES.
A "C" MODE SATIII CAN COMMUNICATE

WITH 8 DEVICES TOTAL.

"D" MODE ADDRESSING NOTES
"D" MODE SAT III ADDRESSING STARTS
AT ADDRESS 4.

EACH "D" MODE SAT III TAKES UP 4
SAT III LOGICAL ADDRESSES.

A "D" MODE SAT III CAN COMMUNICATE
WITH 32 DEVICES TOTAL.

SAT IIICD

Communications Interface

TUC XMIT

ON OFF

ON OFF

SAT ADDRESS

1

STATUS

LOCAL SET

16

4
2

8

64
32

128

LOCAL SET DISABLE

OPTION 2

LOCAL SET

OPTION 1

TEST

BATT ON/ OFF

TUC REC

SAT XMIT

SAT REC

OE320

TUC-2R

W
A
R
M
E
R

C
O
O
L
E
R

OVR

OE213
TYPICAL
SPACE
SENSOR

OE455

SAT 3D

CONTROLLER

VAV BOX

PL102335
RS-485 TO FIBER
OPTIC ADAPTOR

USED IN MULTIPLES
OF TWO

PL102335
RS-485 TO FIBER
OPTIC ADAPTOR

SAT COMM LOOP

SAT COMM LOOP

SAT COMM LOOP

UP TO 32 TOTAL
FAN COIL, HEAT PUMP
PD VAV TERMINAL UNITS
PI VAV TERMINAL UNITS
PARALLEL FAN BOX, ETC.

TUC COMM LOOP

OPTION 4
OPTION 3

OPTION 4
OPTION 3

Advertising