Connect surge protection and power, Attach the pole-mount cabinet – Wavetronix SmartSensor HD (101-0415) - Quick-reference Guide (Installer) User Manual

Page 3

Advertising
background image

7

Connect surge protection and power

1 Attach the mounting brackets to the back of the pole-mount box;

thread in the mounting straps.

2 Position the pole-mount box onto the pole and attach the box to

the pole using the mounting straps.

3 Run the sensor/homerun cables through the cable grips on the bot-

tom of the pole-mount box.

SmartSensor HD normally ships with one of two cable types. Newer installations will use the 8-conduc-

tor cable, but some installations may still use the 9-conductor cable. The wiring of these cables differs very

slightly. The image below shows the wiring of the 8-conduc-

tor cable; below that, the differences in wiring the 9-conduc-

tor cable are explained.

This covers the basics of how to wire the Click 200:
1 Disconnect the Click 200 from the DIN rail.

2 Disconnect the green screw terminals on the appropriate

side of the Click 200 and wire the sensor cable as shown

in the diagram.

3 Connect the Click 200 to the DIN rail.

4 Connect the ground terminal to the DIN rail and the

earth ground wire to the lug bolt on the bottom of the

pole-mount box.

5 Connect the exterior lug bolt to earth ground.

6 Connect 10–30 VDC to the +DC and –DC terminals on

the appropriate side of the Click 200.

Note. The Click 200 has one side marked PROTECTED and

one marked UNPROTECTED; which you use depends on

your installation. If you’re unsure which side to use, consult

the installation designs, Chapter 2 of the SmartSensor HD

User Guide, or Wavetronix Technical Services.

6

Attach the pole-mount cabinet

Note. If you have a 9-conductor cable, it will have the following wiring differences:

˽

There is a gray ground wire that can be plugged into any GND terminal.

˽

Instead of one drain, there are three; they can also be plugged into any GND terminals.

˽

The white +485 wire does not have a blue stripe.

-DC (Black)

+DC (Red)

+485 (White)

-485 (Blue)

CTS (Brown)

RTS (Orange)

Drain

TD (Yellow)

RD (Purple)

Advertising