Westermo ODW-720-F2 User Manual

Page 14

Advertising
background image

14

6651-2235

Data transport in redundant ring, Y-mode configuration

RX2

TX2

Device 1

Sending

Device 2

Receiving

Device 3

Receiving

Device n

Receiving

TX1

RX1

RX2

TX2

TX1

RX1

RX2

TX2

RS-232

RS-232

RS-232

Fibre

pair

Fibre

pair

Fibre

pair

Focal point

RS-232

TX1

RX1

RX2

TX2

TX1

RX1

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

Data from comminication device 1 is received at the ODW-720 RS-232 port (as indi-
cated by the TD LED), data bits are retimed according to the preset rate and sent out
on the optical fibre TX1. The next ODW-720 unit receives data at optical fibre RX2 (as
indicated by the RD LED), and data is sent out on the RS-232 port. Data is also repeated
out on TX1 on to the next ODW-720 unit.

RX2

TX2

Device 1

Receiving

Device 2

Receiving

Device 3

Sending

Device 4

Receiving

TX1

RX1

RX2

TX2

TX1

RX1

RX2

TX2

RS-232

RS-232

RS-232

Fibre

pair

Fibre

pair

Fibre

pair

Focal point

RS-232

TX1

RX1

RX2

TX2

TX1

RX1

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

Data from some other communication device, for example device 3, is processed in the
same way and sent out on both optical fibres TX1 and TX2. Notice that the Ring Focal
point never repeats incoming data.