6651-2235

Data transport in redundant ring, dual channel, V-mode configuration

The first ODW-720 unit recieives data from communications device 1 on the RS-232
port and sends it out on optical fibre TX1 using the primary data channel.
The second ODW-720 unit receives primary channel data on optical fibre RX2. Primary
channel data is repeated out on optical fibre TX1. The second ODW-720 unit also
receives data from communications device 2 on the RS-232 port. The RS-232 data is sent
out on optical fibre TX1 using the secondary data channel.
The third and fourth ODW-720 units receive both primary and secondary channel data
on optical fibre RX2. Both primary and secondary data are repeated out on optical fibre
TX1, but only the primary channel data is sent out on the RS-232 port.
The fifth ODW-720 unit receives both primary and secondary channel data on optical
fibre RX2, but only the secondary channel data is sent out on the RS-232 port.

RX2

TX2

Device 1

Sending data to

device 3 and 4 on the

primary channel

Device 2

Sending data to
device 5 on the

secondary channel

Device 3

Receiving data from

device 1 on the
primary channel

Device 5

Receiving data from

device 2 on the

secondary channel

TX1

RX1

RX2

TX2

TX1

RX1

RX2

TX2

RS-232

RS-232

RS-232

Fibre

pair

Fibre

pair

Fibre

pair

RS-232

TX1

RX1

RX2

TX2

TX1

RX1

Device 4

Receiving data from

device 1 on the
primary channel

RS-232

Fibre

pair

RX2

TX2

TX1

RX1

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

Primary channel

Focal point

Secondary channel

Focal point

Advertising