Mounting, Removal – Westermo Lynx-x08-F2G-S2 User Manual

Page 15

Advertising
background image

15

6643-2220

Mounting

This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an
apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground.
Snap on mounting, see figure.

Mounting Lynx with integrated DIN-clip:

Removal

Cooling
This unit uses convection cooling.
To avoid obstructing the airflow
around the unit, use the following
spacing rules. Minimum spacing 25 mm
(1.0 inch) above / below and 10 mm
(0.4 inches) left / right the unit.
Spacing is recommended for the use
of unit in full operating temperature
range and service life.

10mm

10mm

Removing Lynx with integrated DIN-clip:
Press down the support at the back of the unit using a screwdriver. See figure.