Westermo Lynx-x08-F2G-S2 User Manual

Page 7

Advertising
background image

7

6643-2220

Mechanical
IEC 60068-2-6,
vibration

IEC 60068-2-6,(sine), operating
3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g
5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g
IEC 60068-2-64 (random), operating
5 – 20 Hz: 2 m²/s³,
20 – 2000 Hz: – 3 dB/oct

IEC-60068-2-27, shock

Operating:
30 g, 11 ms
100 g, 6 ms**

IEC 60068-2-27, bump

Operating:
10 g, 11 ms

Interface specifications, power
Rated voltage

24 to 48 VDC

Operating voltage

19 to 60 VDC

Rated current

250 mA (380 mA) @ 24 VDC (with 500 mA USB load)
120 mA (188 mA) @ 48 VDC (with 500 mA USB load)

Rated frequency

DC

Inrush current

22.7·10-3 A²s @ 48 VDC

Startup current*

2 x Rated current

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

* External supply current capability for proper start-up

Interface specifications, 10/100BaseTX
Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

10 Mbit/s, 100 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Circuit type

TNV-1

Transmission range

Up to 150 m with CAT5e cable or better*

Isolation to

All other

Connection

RJ-45, auto MDI/MDI-X

Cabling

Shielded CAT5e or better is recommended

Conductive housing

Yes

Number of ports

4

* Refer to Safety section.

Advertising