6643-2220

Interface specifications, 100/1000SFP
Optical/Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

100 Mbit/s or 1000 Mbit/s transceivers supported

Duplex

Full or Auto, depending on transceiver

Transmission range

Depending on tranceiver

Connection

SFP slot holding fibre transceiver or copper transceiver

Number of ports

1 or 2

Interface specifications, RS-232
Electrical specification

EIA RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits

Protocol

Transparent, optimised by packing algorithm

Circuit type

SELV

Transmission range

15 m / 49 ft

Isolation to

All other

Connection

RJ-45 according to EIA-561

Shielded cable

Recommended

Conductive housing

Yes

Number of ports

1

Interface specifications, RS-422/485
Electrical specification

Configurable for EIA RS-232 or EIA RS-422/485

Data rate

50 bit/s – 2 Mbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set)

Circuit type

TNV-1

Transmission range

Up to 1200 m / 0.74 mi, depending on data rate and cable
type

Isolation to

All other

Connection

RJ-45 according to EIA-561

Shielded cable

Not required, but recommended in railway installations close
to the rails.*

Conductive housing

Yes

Number of ports

1

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m