Type tests and environmental conditions – Westermo TD-23 User Manual

Page 7

Advertising
background image

7

6600-2204

Electromagnetic Compatibility
Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 6 kV

Enclosure air

± 8 kV

RF field AM

modulated

IEC 61000-4-3

Enclosure

6 V/m 80% AM (1 kHz) 2000 – 2700 MHz

10 V/m 80% AM (1 kHz), 80 – 1000 MHz

20 V/m 80% AM (1 kHz), 80 – 2000 MHz

RF field 900 MHz

ENV 50204

Enclosure

20 V/m pulse modulated 200 Hz, 900 ± 5 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports unbalanced ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power frequency

magnetic field

EN 61000-4-8

Enclosure

100 A/m, 50 Hz, 16.7 Hz & 0 Hz

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m, 6.4 / 16 µs pulse

Voltage dips

and interruption

EN 61000-4-11

AC power ports

10, 20, 5000 ms interruption

10 & 500 ms, 30% reduction

200 ms, 60% reduction

Mains freq. 50 Hz

EN 61000-4-16

Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to line

Voltage dips

and interruption

EN 61000-4-29

DC power ports

10 & 100 ms, interruption

500 ms, 30% reduction

10 ms, 60% reduction

+20% above & –20% below rated voltage

Radiated emission

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission

EN 55022

AC power ports

Class B

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Dielectric strength

EN 60950

Signal port to other

isolated ports

2 kVrms 50 Hz 1 min

Power port to other

isolated ports

3 kVrms 50 Hz 1 min

2 kVrms 50 Hz 1 min (@ rated power <60 V)

Environmental
Temperature

Operating

–25 to +70°C

Storage & Transport

–30 to +70°C

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz

2 g, 8 – 500 Hz

Shock

IEC 60068-2-27

Operating

15 g, 11 ms

Packaging
Enclosure

UL 94

PC / ABS

Flammability class V-1

Dimension W x H x D

55 x 100 x 132 mm

Weight

0.25 kg

Degree of protection

IEC 529

Enclosure

IP 20

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail

Type tests and environmental conditions