Interface specifications – Westermo DR-270 User Manual

Page 10

Advertising
background image

10

6622-2241 29000589, REV.A

Interface specifications

Power
Rated voltage

9 – 36 VDC

Operating voltage

9 – 36 VDC

Power consumption

DR-270 – typical:
1.02 A = 12.24 W, max: 1.03 A = 12.36 W
DR-270 + WiFi – typical:
1.12 A = 13.44 W, max: 1.140 A = 13.68 W
DR-270 + 3G – typical:
1.23 A = 14.76 W, max: 1.24 A = 14.88 W
DR-270 + 3G + Wi-Fi – typical:
1.31 A = 15.72 W, max: 1.42 A = 17.04 W

Rated frequency

DC

RS-232
Electrical specification

EIA RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits

Protocol

Transparent, optimised by packing algorithm

Circuit type

SELV

Transmission range

15 m / 49 ft

Connection

9 pin D-sub female

Shielded cable

Not required

Conductive housing

Yes

Number of ports

1

Ethernet TX
Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

10 Mbit/s, 100 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Circuit type

SELV

Transmission range

100 m / 328 ft

Isolation to

All other

Connection

RJ-45 auto MDI/MDIX

Shielded cable

Not required, except when installed in Railway applications as signalling
and telecommunications apparatus and located close to rails.*

Conductive housing

Yes

Number of ports

4

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.
The cable shield should be properly connected (360º) to an earthing point within 1 m from this port.
This earthing point should have a low impedance connection to the conductive enclosure of the apparatus
cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing
system of an installation and may be directly connected to the protective earth.

Advertising