Type tests and environmental conditions – Westermo DR-270 User Manual

Page 6

Advertising
background image

6

6622-2241 29000589, REV.A

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 4 kV

Enclosure air

± 8 kV

RF field AM modulated

EN 61000-4-3

Enclosure

3 V/m 80% AM (1 kHz), 80 – 1000 MHz,
1400 MHz – 2000

Fast transient

EN 61000-4-4

Signal ports

± 0.5 kV

Power ports

± 1 kV

Surge

EN 61000-4-5

Telecom/Signal ports

± 0.5 kV line to earth

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Power ports

3V/m 80% AM (1 kHz), 0.15 – 80 MHz

Voltage dips and
interruption

EN 61000-
4-11

AC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage

Radiated emission

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission

EN 55022

AC power ports

Class A

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Temperature

Operating
DR-270
DR-270 + 3G

–40 to +75º Celsius
–40 to +167º Fahrenheit

Operating
DR-270 + 3G + WiFi
DR-270 + WiFi

–20 to +75º Celsius
–68 to +167º Fahrenheit

Storage & Transport

–40 to +85º Celsius
–40 to +185º Fahrenheit

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2000 m / 70 kPa

Reliability prediction
(MTBF)

Bellcore
RQGR at
40°C

Models and their values
DR-270

125361 h

DR-270 + WiFi

105455 h

DR-270 + 3G

105015 h

DR-270 + 3G + WiFi 90677 h

Enclosure

Pressed steel

Dimension W x H x D

262 x 40.5 x 141 mm
10.3 x 1.6 x 5.5 inches

Weight

1.4 kg

Degree of protection

IEC529

Enclosure

IP 30

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail or flat
on level surface

Advertising
This manual is related to the following products: