13.4 Environmental Specification

Indoor use or corresponding environment
Altitude up to 2000M
Operating temperature (-40 .. +65’C) (55deg on F8)
Humidity 5-95’C
Enclosure IP40

13.4.1 Climatic


Cold

IEC 68-2-1 Ad (-40 ‘C operational 16 Hours)

Storage

IEC 68-2-1 Ad (-40 ’C 16 Hours)

Dry Heat

IEC 68-2-2 Bd (+70 ’C operational 16 Hours)

Humidity

IEC 68-2-30 Db (25 ‘C .. 55 ‘C 95% 6 Cycles 24 Hours)

13.4.2 Mechanical


Oscillation

IEC 255-21-1 Class 1

Shock

IEC 255-21-2 Class 1

Enclosures

IEC 529, IP 40

13.4.3

Electromagnetic Compatibility (EMC)


Industrial Immunity

EN 61000-6-2

Industrial Emission

EN 50081-2

Home / Office Emission EN 50081-1

13.4.4 Radiated

Immunity


ESD

EN 61000-4-2 (4/8 kV)

Magnetic Field

EN 61000-4-8 (300A/m)

RF Field Disturbance

EN 61000-4-3

10

V/m

80%

AM

80

..

1000MHz

13.4.5 Conducted

Immunity



Fast

Transients

EN

61000-4-4

AC/DC

2kV,

Signal

1kV


Surge

Immunity

EN

61000-4-5

AC: 2kV/1kV

DC:

0.5kV/0.5kV