Tcd-2100 hardware manual – ACTi TCD-2100 User Manual

Page 9

Advertising
background image

www.acti.com


TCD-2100 Hardware Manual

9

On (3s)

On

1s

Power On

About 20 Seconds

Stay On

Off (about 15s)

Off (10~15s)

Restore to Default

Complete

8) Terminal Blocks for Digital Input / Output

The IP device supports one alarm input and one transistor output. Please connect DI with Pin 1

and 3 and connect DO with Pin 2 and 4.

9) Ethernet Port

The IP device connects to the Ethernet via a standard RJ45 connector. Supporting NWAY, this

IP device can auto detect the speed of local network segment (10Base-T/100Base-TX

Ethernet).

PIN

NAME

1

GND

2

DC + 12V

3

Digital Input

4

Transistor Output

DI

Connection design

TTL-compatible logic levels

Voltage

To trigger (low)

Logic level 0:

0V ~ 0.4V

Normal (high)

Logic level 1:

3.1V ~ 30V

Current

10mA ~ 100mA

DO

Connection design

Transistor (Open Drain)

Voltage & Current

Internally powered at 12 V. Limit to no more than

24V DC if connected to external power, <100mA

Advertising