Ericsson LBI-39224 User Manual

Page 149

Advertising
background image

LBI-39224

3-119

Emergency Clear Silences Alarm
Select this check box to enable the EMERGENCY tone to be silenced
when the EMERGENCY is cleared by anyone. Unselect to disable, the
tone will remain until cleared by dispatcher.

Minimum Alarm Volume
This is the minimum level at which an emergency tone will be heard.
The greater of the module volume or this volume will be used for the
emergency tone level. Select this value (0 - 32) from the drop-down list
box.

Auto Programmed Alarm Volume
This is the volume setting for incoming non-monitored emergency calls.
Select this value (0 - 32) from the drop-down list box.

Table 4 Console Individual Call Levels

INDIVIDUAL

CALL PRIVILEGE

CEC/IMC

MANAGER

CONFIGURATION

CONSOLE EFFECT

disabled (no Individual

Call privileges)

all units must be

removed from the

console's privilege list

(See Section 3.11.4)

a dispatcher cannot

make or monitor any

Individual Call

partial

desired units are

enabled in the console's

privilege list and the

"Monitor ICALL

Privilege" is disabled

(check box unselected)

a dispatcher can make

Individual Calls to

units on the privilege

list but cannot monitor

any Individual Call

full (Supervisor

console set-ups only)

desired units are

enabled in the console's

privilege list and the

"Monitor ICALL

Privilege" is enabled

(check box selected)

a dispatcher can make

Individual Calls to any

unit and can monitor

any Individual Call

Save and Send Console User Profile Configurations

When the console user profile configuration is complete, save (write)
the new configuration to the CEC/IMC Manager hard disk. Failure to
perform this function may result in loss of the configuration database
for this console. The user profile configurations must be sent to the
respective console before they will take effect. These actions are

Advertising