Ericsson LBI-39224 User Manual

Page 246

Advertising
background image

LBI-39224

4-8

Table 11 Licensed MSC Type

License Value

MSC Type

Description

0

IMC

Default value if license is not present,

multiple site interface

1

CEC

Dispatch Console interface to single

trunked site

2

StarGate

StarGate controller in StarGate

Network

3

Remote CEC

Console Only interface, used to

remotely connect multiple dispatch

consoles to a CEC or IMC

Max Sites
This license specifies the number of MIMs (Site interfaces) that can be
configured in the CEC/IMC. The value may range from 1 to 32.

Max Consoles
This license specifies the number of CIMs (Console interfaces) that can
be configured in the CEC/IMC. The value may range from 1 to 32.

Max Network
This license specifies the number of NIMs (Network interfaces) that can
be configured in the CEC/IMC. The value may range from 1 to 8. This
license applies to StarGate interfaces and Remote CEC interfaces. The
following license (Min Remote CEC) is also required to specify which
type of Network interfaces are desired

Min Remote CEC
This license specifies the number of Remote CEC NIMs required in the
CEC/IMC. The value may range from 0 to 8. Beyond this limit
StarGate NIMs may be configured up to the previous license limit (8).

Max Causeway
This license specifies the maximum number of Causeway (hard)
Patch/Simulselects allowed for the CEC/IMC.

Max Site Chan
This license specifies the number of CEC/IMC TDM Bus slots that are
required for MIM devices. Each site channel requires an allocated
TDM Bus slot to be used for wide area or console dispatch calls.