ARM Electronics DVRHD User Manual

Page 35

Advertising
background image

DVR User’s Manual

34

Use the Direction keys to move the cursor and press ENTER to select or
de-select a grid. Press MODE to select all of the grids for detection; press
MODE again to de-select all of the grids.

Sensitivity
This item is used to set the sensitivity of detection grids for the camera. A
greater value indicates more sensitive motion detection. A motion alarm will
be triggered once the amount of motion detected exceeds the Threshold
value.

Move the cursor to <Sensitivity> and press ENTER, and then use UP/ DOWN
keys to adjust the value. The value is increased by 4% increment.

Block Threshold
<Block Threshold> indicates the motion alarm triggered level. Select from
<1> to <16>. Selecting <1> means the DVR will trigger the alarm when one
grid is detected; and selecting <16> means the DVR will trigger the alarm
when 16 grids are detected. Move the cursor to <Block Threshold> and press
ENTER, and then use UP / DOWN keys to adjust the value.

3.7.8.6

Alarm In

This item allows users to enable/ disable alarm input detection. According to
users’ application, select <N/O> (Normal Open) or <N/C> (Normal Close) to
enable the alarm input detection, or select <OFF> to disable the detection.

If <N/C> is selected without installing any device, an alarm will be triggered
and the Event Icon will always display on the monitor until the selection is
changed to <N/O> or <OFF>, or when a device is installed.

3.7.8.7

Alarm Out

This item allows users to enable/ disable the alarm output on the selected
channel to activate the relay. The signal can be a light or siren to caution an
alarm event. Select <ON> to enable the alarm output, or <OFF> to disable.

Advertising