16) RECORD QUALITY

4 options are available from the drop-down menu: BEST, HIGH, NORMAL and BASIC.

17) TOTAL IPS SHARE

Choose the total IPS share as FIX or GROUP. The more IPS one channel gets, the more smoother the recorded video

will be played.

Press “APPLY” to confirm the setup, or “EXIT” to quit without saving.

7.5.3 Alarm

In “Alarm” and its sub-menu “Alarm List”, you can activate the alarm-trigger function, view the detailed information of

alarm events, and play the event recording.

Press “Alarm”, and you will see the following options:

‧ Alarm Trigger

Select to turn the alarm-trigger function on (Enable) or off (Disable).

‧ Alarm Method

Select the notification methods when any alarm is triggered: Email and / or FTP.

a) Email

When this option is checked, MJPEG pictures will be saved in the path assigned in “General”  “File Path” 

“Snapshot Path” and a copy will also be emailed to the E-mail address assigned in “Network”  “Mail” if any alarm is

triggered.

b) FTP

When this option is checked, MJPEG pictures will be saved in the path assigned in “General”  “File Path” 

“Snapshot Path” and a copy will also be uploaded to the FTP address assigned in “Network”  “FTP” if any alarm is

triggered.

‧ Post Numbers

Set the number of MJPEG pictures (1-10) which will be sent with the chosen alarm method(s).

‧ Alarm Duration

Set the duration time of motion trigger recording (5 SEC / 10 SEC / 20 SEC / 40 SEC).

‧ Auto switch to alarm video

Check this option to immediately switch to the channel that an alarm event is triggered and see the live view.

‧ Alarm Refresh

Press to clear the alarm icon “