TROUBLESHOOTING

As a troubleshooting aid, reference signal status and presence, as well as power and CPU status can be

easily monitored from the front panel of the 7160 module using the front panel indicators.

Refer to the troubleshooting tips below:

Can’t control module

Check status of CPU Run green LED. Should be blinking slowly and in unison with other

modules if System module is present. If not, try removing it and plugging it in again to be sure

it is seated properly.

System module may not be working properly if installed.

Module remote controls are grayed out

Module is locked or access to module controls is restricted by User Level.

No signal out of module

Check status of Active LEDs. Primary or Secondary should be lit. If not, check the inputs for

signal presence and quality.

Check cabling to input of the module.

Please also refer to the technical support section of the Ensemble Designs web site for the latest

information on your equipment at the URL below:

http://www.ensembledesigns.com/support

SOFTWARE UPDATES

Software updates for each module can be downloaded remotely if the optional System Control

module is installed. These can be downloaded onto your PC, then Avenue PC will distribute the update

to the individual module. (Refer to the Avenue PC documentation for more information) Updates are

periodically posted on the Ensemble Designs web site. If you do not have the required System Control

Module and Avenue PC, modules can be sent back to the factory for software upgrades.