Verifying the configuration – H3C Technologies H3C S12500-X Series Switches User Manual

Page 361

Advertising
background image

347

[SwitchB] bfd session init-mode active

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] ospfv3 bfd enable

[SwitchB-Vlan-interface10] bfd min-transmit-interval 500

[SwitchB-Vlan-interface10] bfd min-receive-interval 500

[SwitchB-Vlan-interface10] bfd detect-multiplier 6

679B

Verifying the configuration

# Display the BFD information on Switch A.

<SwitchA> display bfd session

Total Session Num: 1 Init Mode: Active

IPv6 Session Working Under Ctrl Mode:

Local Discr: 1441 Remote Discr: 1450

Source IP: FE80::20F:FF:FE00:1202 (link-local address of VLAN-interface 10 on

Switch A)

Destination IP: FE80::20F:FF:FE00:1200 (link-local address of VLAN-interface 10 on

Switch B)

Session State: Up Interface: Vlan10

Hold Time: 2319ms

# Display routes destined for 2001:4::0/64 on Switch A.

<SwitchA> display ipv6 routing-table 2001:4::0 64

Summary Count : 1

Destination: 2001:4::/64 Protocol : OSPFv3

NextHop : FE80::20F:FF:FE00:1200 Preference: 10

Interface : Vlan10 Cost : 1

The output information shows that Switch A communicates with Switch B through VLAN-interface 10. The
link over VLAN-interface 10 fails.
# Display routes to 2001:4::0/64 on Switch A.

<SwitchA> display ipv6 routing-table 2001:4::0 64

Summary Count : 1

Destination: 2001:4::/64 Protocol : OSPFv3

NextHop : FE80::BAAF:67FF:FE27:DCD0 Preference: 10

Interface : Vlan11 Cost : 2

The output shows that Switch A communicates with Switch B through VLAN-interface 11.

Advertising
This manual is related to the following products: