Configuring the dead interval for an interface – H3C Technologies H3C S12500-X Series Switches User Manual

Page 102

Advertising
background image

93

fcid 0x010001

zone name Zone2

fcid 0x010002

pwwn 11:22:33:44:55:66:77:88

zone-alias Alias1

fcid 0x020004

pwwn 22:33:44:55:66:77:88:99

zone name Zone3

fcid 0x010003

zone-alias Alias1

fcid 0x020004

pwwn 22:33:44:55:66:77:88:99

# Display information about Zone 2 in VSAN 1.

<SwitchB> display zone name Zone2 vsan 1

VSAN 1:

zone name Zone2

fcid 0x010002

pwwn 11:22:33:44:55:66:77:88

zone-alias Alias1

fcid 0x020004

pwwn 22:33:44:55:66:77:88:99

# Display information about all zone aliases.

<SwitchB> display zone-alias

VSAN 1:

zone-alias name Alias1

fcid 0x020004

pwwn 22:33:44:55:66:77:88:99

# Display the zone or zone alias to which 020004 (FC ID type) belongs.

<SwitchB> display zone member fcid 020004

fcid 0x020004

VSAN 1:

zone-alias Alias1

zone Zone2

zone Zone3

# Display information about the active zone set in VSAN 1.

<SwitchB> display zoneset active vsan 1

VSAN 1:

zoneset name Zoneset1

zone name Zone1

*fcid 0x010001

zone name Zone2

*fcid 0x010002

*fcid 0x020004

*fcid 0x020005 [pwwn 22:33:44:55:66:77:88:99]

*fcid 0x020006 [pwwn 11:22:33:44:55:66:77:88]

zone name Zone3

*fcid 0x010003

Advertising
This manual is related to the following products: