Remote fault detection – H3C Technologies H3C SR8800 User Manual

Page 20

Advertising
background image

11

the local OAM entity sends an Event Notification OAMPDU to notify the remote OAM entity. With the

log information, network administrators can track network status promptly.

Table 7 Ethernet OAM link error events

Ethernet OAM link events

Description

Errored symbol event

An errored symbol event occurs when the number of
detected symbol errors during a specified detection

interval exceeds the predefined threshold.

Errored frame event

An errored frame event occurs when the number of
detected error frames during a specified interval
exceeds the predefined threshold.

Errored frame period event

An errored frame period event occurs when the
number of frame errors in the specified number of

received frames exceeds the predefined threshold.

Errored frame seconds event

An errored frame seconds event occurs when the
number of error frame seconds detected on a port

during a specified interval reaches the error threshold.

NOTE:

The system transforms the period of detecting errored frame period events into the maximum number of
64-byte frames that a port can send in the specified period. The system takes the maximum number of

frames sent as the period. The maximum number of frames sent is calculated using this formula: the

maximum number of frames = interface bandwidth (bps) × errored frame period event detection period
(in ms)/(64 × 8 × 1000)

A second in which errored frames appear is called an “errored frame second”.

Remote fault detection

Information OAMPDUs are exchanged periodically among Ethernet OAM entities across established

OAM connections. In a network where traffic is interrupted due to device failures or unavailability, the
flag field defined in information OAMPDUs allows an Ethernet OAM entity to send error

information—the critical link event type—to its peer. You can use the log information to track ongoing link

status and troubleshoot problems promptly.

Table 8 Critical link events

Type Description

OAMPDU transmission

frequencies

Link Fault

Peer link signal is lost.

Once per second

Dying Gasp

An unexpected fault, such as
power failure, occurred.

Non-stop

Critical Event

An undetermined critical event
happened.

Non-stop

Advertising