Leds, Interface specifications, Interface cables – H3C Technologies H3C SR6600-X User Manual
Page 41

33
Figure 24 Front panel of MIM-8E1(75)-F
The front panel of MIM-8E1(75)-F is similar to that of MIM-8E1(75).
LEDs
Table 35 LED description
LED Status
Description
LINK/ACT
(Green)
Off
No carrier signals are being received.
On
Carrier signals are being received.
Flashing
Data is being transmitted or received.
LP/AL
(Yellow)
Off
No loopback or alarms have occurred.
On
The interface is in loopback state.
Flashing
A minimum of one alarm of the type of AIS, LFA, or RAI has occurred.
Interface specifications
Table 36 Interface specifications
Item Specification
Connector type
DB-68
Number of interfaces
1
Interface standard
G.703
Interface speed
2.048 Mbps
Interface cable type
75-ohm 8E1 splitter cable
Cable characteristic impedance
75 ohm
Working modes
E1, CE1, and FE1 (supported by the MIM-8E1(75)-F only)
Services supported
•
Backup
•
Terminal access service
Interface cables
The MIM-8E1(75) or MIM-8E1(75)-F provides eight E1 ports and uses a 75-ohm splitter cable. At one
end of this 16-core coaxial cable is a DB-68 connector used to connect to the device, and at the other
end are 16 BNC connectors used to connect to the peer devices.