User-defined variables, Configuring a monitor policy, Configuration restrictions and guidelines – H3C Technologies H3C MSR 5600 User Manual

Page 234: Configuring a monitor policy from the cli

Advertising
background image

221

User-defined variables

You can use user-defined variables for all types of events.
User-defined variable names can contain digits, characters, and the underscore sign (_), but their
leading character cannot be the underscore sign.

Configuring a user-defined EAA environment

variable

Configure a user-defined EAA environment variable before you use it in an action.
To configure a user-defined EAA environment variable:

Step Command Remarks

1.

Enter system view.

system-view

N/A

2.

Configure a
user-defined EAA

environment

variable.

rtm environment var-name
var-value

By default, no user-defined environment
variables are configured. The system provides

the system-defined variables in

Table 30

.

Configuring a monitor policy

You can configure a monitor policy by using the CLI or Tcl.

Configuration restrictions and guidelines

When you configure monitor policies, follow these restrictions and guidelines:

•

Make sure the actions in different policies do not conflict. Policy execution result will be
unpredictable if policies that conflict in actions are running concurrently.

•

You can assign the same policy name to a CLI-defined policy and a Tcl-defined policy, but you
cannot assign the same name to policies that are the same type.

•

The system executes the actions in a policy in ascending order of action IDs. When you add actions
to a policy, you must make sure the execution order is correct.

Configuring a monitor policy from the CLI

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter CLI-defined
policy view.

rtm cli-policy policy-name

If the policy does not exist, this
command creates the policy first.

Advertising