[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0

# Create VLAN 2 and assign GigabitEthernet 1/0/1 to VLAN 2.

[PE1] vlan 2

[PE1-vlan2] quit

[PE1] interface gigabitethernet 1/0/1

[PE1-GigabitEthernet1/0/1] port access vlan 2

# Disable STP on GigabitEthernet 1/0/1, and then enable BPDU tunneling for STP on it.

[PE1-GigabitEthernet1/0/1] undo stp enable

[PE1-GigabitEthernet1/0/1] bpdu-tunnel dot1q stp

2.

Configure PE 2:
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.

<PE2> system-view

[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0

# Create VLAN 2 and assign GigabitEthernet 1/0/2 to VLAN 2.

[PE2] vlan 2

[PE2-vlan2] quit

[PE2] interface gigabitethernet 1/0/2

[PE2-GigabitEthernet1/0/2] port access vlan 2

# Disable STP on GigabitEthernet 1/0/2, and then enable BPDU tunneling for STP on it.

[PE2-GigabitEthernet1/0/2] undo stp enable

[PE2-GigabitEthernet1/0/2] bpdu-tunnel dot1q stp

BPDU tunneling for PVST configuration example

Network requirements

As shown in

Figure 31

:

•

CE 1 and CE 2 are edge devices on the geographically dispersed network of User A. PE 1 and PE
2 are edge devices on the service provider network.

•

All ports that connect service provider devices and customer devices and those that interconnect
service provider devices are trunk ports and allow packets of any VLAN to pass through.

•

PVST is enabled for VLANs 1 through 4094 on User As network.

Configure BPDU tunneling for PVST, so that CE 1 and CE 2 implement consistent PVST calculation across
the service provider network, and the destination multicast MAC address carried in BPDUs is