H3C Technologies H3C SecBlade LB Cards User Manual

Page 133

Advertising
background image

125

Step Command

Remarks

4.

Configure
threshold

monitoring.

•

Enable sending traps to the NMS when specified conditions
are met:

reaction trap { probe-failure consecutive-probe-failures |

test-complete | test-failure cumulate-probe-failures }

•

Configure a reaction entry for monitoring the duration of an

NQA operation (not supported in UDP jitter and voice

operations):
reaction item-number checked-element probe-duration

threshold-type { accumulate accumulate-occurrences |

average | consecutive consecutive-occurrences }
threshold-value upper-threshold lower-threshold [ action-type

{ none | trap-only } ]

•

Configure a reaction entry for monitoring failure times (not

supported in UDP jitter and voice operations):

reaction item-number checked-element probe-fail

threshold-type { accumulate accumulate-occurrences |
consecutive consecutive-occurrences } [ action-type { none |

trap-only } ]

•

Configure a reaction entry for monitoring the round-trip time

(only supported in UDP jitter and voice operations):

reaction item-number checked-element rtt threshold-type

{ accumulate accumulate-occurrences | average }
threshold-value upper-threshold lower-threshold [ action-type

{ none | trap-only } ]

•

Configure a reaction entry for monitoring packet loss (only

supported in UDP jitter and voice operations):

reaction item-number checked-element packet-loss

threshold-type accumulate accumulate-occurrences
[ action-type { none | trap-only } ]

•

Configure a reaction entry for monitoring one-way jitter (only

supported in UDP jitter and voice operations):
reaction item-number checked-element { jitter-ds | jitter-sd }

threshold-type { accumulate accumulate-occurrences |

average } threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]

•

Configure a reaction entry for monitoring the one-way delay

(only supported in UDP jitter and voice operations):
reaction item-number checked-element { owd-ds | owd-sd }

threshold-value upper-threshold lower-threshold

•

Configure a reaction entry for monitoring the ICPIF value

(only supported in the voice operation):

reaction item-number checked-element icpif threshold-value

upper-threshold lower-threshold [ action-type { none |
trap-only } ]

•

Configure a reaction entry for monitoring the MOS value

(only supported in the voice operation):
reaction item-number checked-element mos threshold-value

upper-threshold lower-threshold [ action-type { none |

trap-only } ]

Configure the
trap sending

method as
needed.
No traps are
sent to the NMS

by default.
The reaction
trap command

in voice

operation view
only supports

the

test-complete

keyword.

Advertising