Selecting the display step with linear encoders
To select a certain display step, you must define the
following operating parameters:
 Signal period (P31)
 Counting mode (P33)
 Decimal places (P38)
Example
Linear encoder with a signal period of 20 µm
Desired display step ................ 0.000 5 mm
Signal period (P31) ................... 20
Counting mode (P33) ............... 5
Decimal places (P38) ............... 4
The table overleaf will help you select the
parameters.