Troubleshooting – Epson ELP-600 User Manual

Page 84

Advertising
background image

82

Tip :

• If the projector is not operating properly even though the indicators are all showing

normal, refer to "When the Indicators Provide No Help" on the following page.

• If an indicator is showing a status which does not appear in the previous tables,

contact your dealer or the nearest address provided at “International Warranty
Conditions” in Safety Instructions/World-Wide Warranty Terms included in the
package.

High-speed
cooling in
progress

(This is not an abnormality, but if the
temperature rises too high again, projection
will stop automatically.)

• Set the projector up in a place which is

well-ventilated, and so that the air inlet and
exhaust vents are clear.

• Clean the air filter.

P.18
P.92

Lamp will soon
need to be
replaced.

Have a new replacement lamp ready.
The lamp service life can become shorter than
normal as a result of the usage conditions,
and so the lamp should be replaced as soon as
possible.

* The appearance of the operation indicator

at this time will vary depending on the sta-
tus of the projector.

P.94

Standby
condition

(No abnormality)
Projection starts when the [Power] button is
pressed.

P.37

Warm-up in
progress

(No abnormality)
Wait for a short while. The indicator will stop
flashing and light with a green color.

P.37

Projecting in
progress

(No abnormality)

P.37

Cool-down in
progress

(No abnormality)

• Wait for a short while.

The cool-down

(lamp cooling operation)

period lasts for about 2 minutes. The actual
time will vary depending on the external air
temperature.

• The [Power] button will not operate during

the cool-down period. When cool-down is
complete, the indicator will stop flashing
and light orange. You can then use the
[Power] button.

P.39

Indicator status

Projector

status

Problem and remedy

Reference

page

red

orange

orange

orange

green

green

orange

Troubleshooting