HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 396
Advertising

396
Touch Probe Cycles: Automatic Datum Setting
15.1
0
D
A
TUM CIR
C
LE CENTER (Cy
c
le
416, DIN/ISO:
G416)
Probe TS axis: Coord. 3rd axis
Q384 (absolute):
Coordinate of the probe point in the touch probe axis,
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999
New datum in TS axis
Q333 (absolute): Coordinate in
the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range -99999.9999
to 99999.9999
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140, and is only effective when the
datum is probed in the touch probe axis. Input range
0 to 99999.9999; alternatively PREDEF
Advertising