1

General safety notes

Observe the country-specific installation, safety, and accident prevention regulations.

During startup and servicing, observe the five safety rules according to DIN EN 50110-1.

Generally speaking, the rules are to be adhered to in the specified order:

Disconnect safely

Ensure power cannot be switched on again

Verify safe isolation from the supply

Ground and short circuit

Cover or safeguard adjacent live parts

Once the work is complete, perform the above steps again in reverse order.

Intended use of the Phoenix Contact product

Important: Read the instruction manual carefully before mounting, installing, and starting

up the CBL-DC-CMB1-10. Pay particular attention to the safety notes in this document.

Store the document in a safe place for later use.

WARNING: Incorrect handling of the CBL-DC-CMB1-10 can pose serious risks for

the user.

The Phoenix Contact product may only be operated in accordance with the information in

this instruction manual. The use of third-party products and components must be recom-

mended or approved by Phoenix Contact with reference to the associated technical doc-

umentation.

The error-free and safe operation of the product can only be guaranteed with proper trans-

port, proper storage, assembly, mounting, installation, startup, operation, and servicing.

The permitted ambient conditions must be adhered to. All information in the associated

documentation must be observed. Otherwise there is a risk of electric shock or material

damage.

WARNING: Dangerous contact voltage

Never open the lever-type fuse terminal blocks under load!

All work on the device must only be carried out by qualified personnel who are familiar

with the necessary safety precautions.

Before working on the device, disconnect the power.

Do not open the CBL-DC-CMB1-10 during operation. The device or device compo-

nents are live.

The CBL-DC-CMB1-10 must not be used in grounded PV systems.

Protect the CBL-DC-CMB1-10 against reverse currents from the inverter. A maxi-

mum reverse current equal to the nominal current of the string combiner box is per-

mitted. Make sure that the documented technical data is observed.

The connecting cables of the photovoltaic system may still be live even when the

switch disconnector (if present) is open. Make sure that the power is disconnected

when carrying out installation and servicing work.

WARNING: Risk of burns

Under full load, the internal components or cables can become very hot (> 50°C).