Device Description

Operating Instructions

16

SMA Regelsysteme GmbH

SB2800i-11:FE0504

Stop

The Sunny Boy 2800i is in stop state. This is to calibrate the
measurement electronics, subsequently the inverter switches into
„ Waiting“ state.

The „ Stop“ state can also be set manually by the plant operator
using the Sunny Boy Control or the PC program Sunny Data or
Sunny Data Control. In this case, the Sunny Boy 2800i remains in
„ Stop“ state until a new operating state is defined („ MPP
operation“ or „ Constant voltage operation“).

Waiting, Grid Monitoring

The Sunny Boy 2800i is testing whether start-up conditions for
feeding operation are fulfilled (starting voltage, starting time) and
then starts to monitor the grid.