SB2800i-11:FE0504

Input current as a function of the input voltage

Fig. 6.1: Input current I

PV

as a function of the input voltage U

PV

6.3 General Data

You will find a detailed device description in chapter 3 "Device Description" (page 7) of these
Operating Instructions.

General Data
Protection Degree according to DIN EN 60529 IP21 (inside installation)
Dimensions (width x height x depth)

approx. 440 mm x 305 mm x 226 mm

Weight

approx. 31 kg

External interfaces
Data transmission via Powerline

optional

Data transmission via separate data cable

optional,
RS232 / RS485, electrically separated

Efficiency
Max. Efficiency

η

max

> 94 %

European Weighted Efficiency

η

euro

> 93 %